Monitoring Benefit
The GC test verifies that each DC or RODC can connect locally to Global Catalog and that LSASS is listening for Global Catalog connections.
How do we verify the results received on the EMS web server?
From the EMS web server, open the following file from Explorer using a browser:
\Program Files (x86)\ENow\MailscapeWeb\MailscapeData\LogFiles\ServerName\NetworkAgentMessage.xml
Scroll to the bottom of the results and locate GC Port3269, Port3268, and BindTime to verify that the results match what is presented on the monitoring web page.
How do we verify the results received on the Compass client?
From the DC or RODC, open the following file from Explorer using Notepad:
\Program Files (x86)\ENow\Mailscape Agent\LogFiles\MailscapeAgent2007.log
Find the string “GC bind” in the log and note the GC bind results and any errors that may follow. If an error is detected where the port is unavailable, we recommend running Portqry from the EMS web server to the DC or RODC in question.